TY - JOUR
T1 - Comparison of workplace protection factors for different biological contaminants
AU - Jacobcho, Kyungmin
AU - Reponen, Tiina
AU - McKay, Roy
AU - Dwivedi, Alok
AU - Adhikari, Atin
AU - Singh, Umesh
AU - Shukla, Rakesh
AU - Jones, Susan
AU - Jones, Gordon
AU - Grinshpun, Sergey A.
PY - 2011
Y1 - 2011
N2 - This study compared workplace protection factors (WPFs) for five different contaminants (endotoxin, fungal spores, (1→3)-β-D-glucan, total particle mass, and total particle number) provided by an N95 elastomeric respirator (ER) and an N95 filtering facepiece respirator (FFR). We previously reported size-selective WPFs for total particle numbers for the ER and FFR, whereas the current article is focused on WPFs for bioaerosols and total particle mass. Farm workers (n = 25) wore the ER and FFR while performing activities at eight locations representing horse farms, pig barns, and grain handling facilities. For the determination of WPFs, particles were collected on filters simultaneously inside and outside the respirator during the first and last 15 min of a 60-min experiment. One field blank per subject was collected without actual sampling. A reporting limit (RL) was established for each contaminant based on geometric means (GMs) of the field blanks as the lowest possible measurable values. Depending on the contaminant type, 38–48% of data points were below the RL. Therefore, a censored regression model was used to estimate WPFs (WPF censored). The WPF censored provided by the two types of respirators were not significantly different. In contrast, significant differences were found in the WPF censored for different types of contaminants. GMs WPF censored for the two types of respirators combined were 154, 29, 18, 19, and 176 for endotoxin, fungal spore count, (1→3)-β-D-glucan, total particle mass, and total particle number, respectively. The WPF censored was more strongly associated with concentrations measured outside the respirator for endotoxin, fungal spores, and total particle mass except for total particle number. However, when only data points with outside concentrations higher than 176×RL were included, the WPFs increased, and the association between the outside concentrations and the WPFs became weaker. Results indicate that difference in WPFs observed between different contaminants may be attributed to differences in the sensitivity of analytical methods to detect low inside concentrations, rather than the nature of particles (biological or non-biological).
AB - This study compared workplace protection factors (WPFs) for five different contaminants (endotoxin, fungal spores, (1→3)-β-D-glucan, total particle mass, and total particle number) provided by an N95 elastomeric respirator (ER) and an N95 filtering facepiece respirator (FFR). We previously reported size-selective WPFs for total particle numbers for the ER and FFR, whereas the current article is focused on WPFs for bioaerosols and total particle mass. Farm workers (n = 25) wore the ER and FFR while performing activities at eight locations representing horse farms, pig barns, and grain handling facilities. For the determination of WPFs, particles were collected on filters simultaneously inside and outside the respirator during the first and last 15 min of a 60-min experiment. One field blank per subject was collected without actual sampling. A reporting limit (RL) was established for each contaminant based on geometric means (GMs) of the field blanks as the lowest possible measurable values. Depending on the contaminant type, 38–48% of data points were below the RL. Therefore, a censored regression model was used to estimate WPFs (WPF censored). The WPF censored provided by the two types of respirators were not significantly different. In contrast, significant differences were found in the WPF censored for different types of contaminants. GMs WPF censored for the two types of respirators combined were 154, 29, 18, 19, and 176 for endotoxin, fungal spore count, (1→3)-β-D-glucan, total particle mass, and total particle number, respectively. The WPF censored was more strongly associated with concentrations measured outside the respirator for endotoxin, fungal spores, and total particle mass except for total particle number. However, when only data points with outside concentrations higher than 176×RL were included, the WPFs increased, and the association between the outside concentrations and the WPFs became weaker. Results indicate that difference in WPFs observed between different contaminants may be attributed to differences in the sensitivity of analytical methods to detect low inside concentrations, rather than the nature of particles (biological or non-biological).
KW - Agriculture
KW - Bioaerosol
KW - Respirator
KW - Workplace protection factor
UR - http://www.scopus.com/inward/record.url?scp=80155175162&partnerID=8YFLogxK
U2 - 10.1080/15459624.2011.585094
DO - 10.1080/15459624.2011.585094
M3 - Article
SN - 1545-9624
VL - 8
SP - 417
EP - 425
JO - Journal of Occupational and Environmental Hygiene
JF - Journal of Occupational and Environmental Hygiene
IS - 7
ER -