TY - JOUR
T1 - Elemental assessment of vegetation via portable X-ray fluorescence (PXRF) spectrometry
AU - McGladdery, Candice
AU - Weindorf, David C.
AU - Chakraborty, Somsubhra
AU - Li, Bin
AU - Paulette, Laura
AU - Podar, Dorina
AU - Pearson, Delaina
AU - Kusi, Nana Yaw O.
AU - Duda, Bogdan
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/3/15
Y1 - 2018/3/15
N2 - Elemental concentrations in vegetation are of critical importance, whether establishing plant essential element concentrations (toxicity vs. deficiency) or investigating deleterious elements (e.g., heavy metals) differentially extracted from the soil by plants. Traditionally, elemental analysis of vegetation has been facilitated by acid digestion followed by quantification via inductively coupled plasma (ICP) or atomic absorption (AA) spectroscopy. Previous studies have utilized portable X-ray fluorescence (PXRF) spectroscopy to quantify elements in soils, but few have evaluated the vegetation. In this study, a PXRF spectrometer was employed to scan 228 organic material samples (thatch, deciduous leaves, grasses, tree bark, and herbaceous plants) from smelter-impacted areas of Romania, as well as National Institute of Standards and Technology (NIST) certified reference materials, to demonstrate the application of PXRF for elemental determination in vegetation. Samples were scanned in three conditions: as received from the field (moist), oven dry (70 °C), and dried and powdered to pass a 2 mm sieve. Performance metrics of PXRF models relative to ICP atomic emission spectroscopy were developed to asses optimal scanning conditions. Thatch and bark samples showed the highest mean PXRF and ICP concentrations (e.g., Zn, Pb, Cd, Fe), with the exceptions of K and Cl. Validation statistics indicate that the stable validation predictive capacity of PXRF increased in the following order: oven dry intact < field moist < oven dried and powdered. Even under field moist conditions, PXRF could reasonably be used for the determination of Zn (coefficient of determination, R2val 0.86; residual prediction deviation, RPD 2.72) and Cu (R2val 0.77; RPD 2.12), while dried and powdered samples allowed for stable validation prediction of Pb (R2val 0.90; RPD 3.29), Fe (R2val 0.80; RPD 2.29), Cd (R2val 0.75; RPD 2.07) and Cu (R2val 0.98; RPD of 8.53). Summarily, PXRF was shown to be a useful approach for quickly assessing the elemental concentration in vegetation. Future PXRF/vegetation research should explore additional elements and investigate its usefulness in evaluating phytoremediation effectiveness.
AB - Elemental concentrations in vegetation are of critical importance, whether establishing plant essential element concentrations (toxicity vs. deficiency) or investigating deleterious elements (e.g., heavy metals) differentially extracted from the soil by plants. Traditionally, elemental analysis of vegetation has been facilitated by acid digestion followed by quantification via inductively coupled plasma (ICP) or atomic absorption (AA) spectroscopy. Previous studies have utilized portable X-ray fluorescence (PXRF) spectroscopy to quantify elements in soils, but few have evaluated the vegetation. In this study, a PXRF spectrometer was employed to scan 228 organic material samples (thatch, deciduous leaves, grasses, tree bark, and herbaceous plants) from smelter-impacted areas of Romania, as well as National Institute of Standards and Technology (NIST) certified reference materials, to demonstrate the application of PXRF for elemental determination in vegetation. Samples were scanned in three conditions: as received from the field (moist), oven dry (70 °C), and dried and powdered to pass a 2 mm sieve. Performance metrics of PXRF models relative to ICP atomic emission spectroscopy were developed to asses optimal scanning conditions. Thatch and bark samples showed the highest mean PXRF and ICP concentrations (e.g., Zn, Pb, Cd, Fe), with the exceptions of K and Cl. Validation statistics indicate that the stable validation predictive capacity of PXRF increased in the following order: oven dry intact < field moist < oven dried and powdered. Even under field moist conditions, PXRF could reasonably be used for the determination of Zn (coefficient of determination, R2val 0.86; residual prediction deviation, RPD 2.72) and Cu (R2val 0.77; RPD 2.12), while dried and powdered samples allowed for stable validation prediction of Pb (R2val 0.90; RPD 3.29), Fe (R2val 0.80; RPD 2.29), Cd (R2val 0.75; RPD 2.07) and Cu (R2val 0.98; RPD of 8.53). Summarily, PXRF was shown to be a useful approach for quickly assessing the elemental concentration in vegetation. Future PXRF/vegetation research should explore additional elements and investigate its usefulness in evaluating phytoremediation effectiveness.
KW - Elemental concentration
KW - Heavy metals
KW - Portable X-ray fluorescence
KW - Vegetation
UR - http://www.scopus.com/inward/record.url?scp=85040686252&partnerID=8YFLogxK
U2 - 10.1016/j.jenvman.2018.01.003
DO - 10.1016/j.jenvman.2018.01.003
M3 - Article
C2 - 29348058
AN - SCOPUS:85040686252
SN - 0301-4797
VL - 210
SP - 210
EP - 225
JO - Journal of Environmental Management
JF - Journal of Environmental Management
ER -