TY - JOUR
T1 - Reliability of Nerve Function Assessments for People with Peripheral Neuropathy
AU - Zhang, Shuqi
AU - Holmes, Matthew L.
AU - Li, Li
N1 - Publisher Copyright:
© 2014 Informa Healthcare USA, Inc.
PY - 2014/6/4
Y1 - 2014/6/4
N2 - Examining degenerative sensory and reflexive activity among people with peripheral neuropathy (PN) is important for clinical examinations and understanding relevant neural impairments. However, other than the test of presynaptic inhibition, the reliability of other related tests is largely unknown. The purpose of this project was to examine the test-retest reliability of lower extremity sensory and reflexive measures in people with PN. Twelve participants (8 women, 4 men, age = 72.5 ± 9.2 years) diagnosed with PN were assessed on two occasions at least 7 d apart. Plantar sensitivity, H-reflex and active and passive ankle proprioception (AAP and PAP) were tested. Paired student's t-test and Intraclass correlation coefficients (ICC) were used for statistical analysis. Significant difference was observed in AAP at 0 position (p = 0.04). No other significant differences were observed. Moderate to high reliability was observed at measures of Plantar sensitivity (0.92), peak to peak H (0.71) and M (0.84) waves, latency between H and M (0.78), H-Index (0.85), AAP (0.62) and PAP index (0.60). Low reliability was observed of other parameters. The measures of Hmax, Mmax, latency, H-Index, plantar sensitivity and AAP & PAP indices of proprioception tests can be measured reliably for further study in this population.
AB - Examining degenerative sensory and reflexive activity among people with peripheral neuropathy (PN) is important for clinical examinations and understanding relevant neural impairments. However, other than the test of presynaptic inhibition, the reliability of other related tests is largely unknown. The purpose of this project was to examine the test-retest reliability of lower extremity sensory and reflexive measures in people with PN. Twelve participants (8 women, 4 men, age = 72.5 ± 9.2 years) diagnosed with PN were assessed on two occasions at least 7 d apart. Plantar sensitivity, H-reflex and active and passive ankle proprioception (AAP and PAP) were tested. Paired student's t-test and Intraclass correlation coefficients (ICC) were used for statistical analysis. Significant difference was observed in AAP at 0 position (p = 0.04). No other significant differences were observed. Moderate to high reliability was observed at measures of Plantar sensitivity (0.92), peak to peak H (0.71) and M (0.84) waves, latency between H and M (0.78), H-Index (0.85), AAP (0.62) and PAP index (0.60). Low reliability was observed of other parameters. The measures of Hmax, Mmax, latency, H-Index, plantar sensitivity and AAP & PAP indices of proprioception tests can be measured reliably for further study in this population.
KW - Ankle proprioception
KW - H-Reflex
KW - H-index
KW - Peripheral Neuropathy
KW - Reliability
KW - Tactile sensation
UR - https://digitalcommons.georgiasouthern.edu/health-kinesiology-facpubs/8
UR - https://doi.org/10.3109/00207454.2014.920332
U2 - 10.3109/00207454.2014.920332
DO - 10.3109/00207454.2014.920332
M3 - Article
SN - 0020-7454
VL - 125
JO - International Journal of Neuroscience
JF - International Journal of Neuroscience
ER -